• Phase II PTG-5500 [PTG5500] Coating Thickness Gage with Auto-Detect Probe

The PHASE II PTG5500 Coating Thickness Gage with Auto-Detect Probe can perform two different methods of calculating coating thickness measurement by utilizing the characteristics of both eddy current and magnetic induction.

Coating thickness testing performance is both non-destructive and extremely accurate.

With the PTG-5500 state-of-the-art coating thickness gauge, users can easily detect the thickness of nonmagnetic coating on a magnetic substrate (ferrous), or an insulating coating on a non-magnetic conductive substrate (non-ferrous), utilizing the included auto-detect probe

The PTG-5500 coating thickness gauge can be used in many areas of industry, including automotive auctions, manufacturing, general engineering, commercial inspection, etc.

The PTG-5500 coating thickness gauge utilizes a rugged probe that can automatically detect a Ferrous or Non-Ferrous substrate and comes with 2 substrate samples (steel, aluminum), 4 calibrated thickness samples, carrying case, batteries, and an operation manual.

Futures;

  • Coating thickness gage with auto-detect probe
  • Two measuring modes: Single or Continuous (Scan mode/selectable)
  • Automatic temperature compensation: Compensates for measurement distortions caused by changes in temperature
  • Displays five statistical values: Average/MEAN, MAX, MIN, measure number ( No.), and standard deviation (S.DEV)
  • Calibration: Simple 1-step calibration using supplied metal plate and reference shims
  • Data storage: Close to 500 measurements in memory (99 measurements/group x 5 groups); includes data output software and cable
  • Tolerance setting: Alarm when measurements out of tolerance
  • Battery symbol: Displays remaining power in battery
  • Probe type: F/N and F/N
  • Measuring principle: Magnetic induction and Eddy current
  • Measuring range: 0~1500 um (0-59mil) and 0~1500 um (0-59mil)
  • Resolution (selectable): 1 um , 0.1 um, .01um and 1 um , 0.1 um, .01um
  • Zero calibration accuracy: ±(2%H+1) um and ±(2%H+1) um
  • Measuring condition:
    • Min. radius of curvature: Cx. 1.5 mm and Cx. 3 mm
    • Min. radius of area: Φ7 mm and Φ5 mm
    • Critical thickness of plate: 0.5 mm and 0.3 mm

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha

Phase II PTG-5500 [PTG5500] Coating Thickness Gage with Auto-Detect Probe

  • Brand: Phase II
  • Product Code: PTG-5500
  • Availability: Pre-Order
  • Rp.0